35Installation instructions geoTHERM VWS/VWW 0020057444_01
6.7.5 Mixer circuit with buffer cylinder and
domestic hot water cylinder
(Hydraulic plan 4)
The unregulated underfloor heating circuits are operat-
ed by the external heating circuit pump from the buffer
cylinder via a mixer. The flow temperature sensor sits
behind the external pump.
The heat pump responds to a demand for heat from the
buffer cylinder.
SP
42a
AF
43
25
KW
42b
32
VF1
46 VF227
RF1
55
30
31
30
30
31
M
WQ
33
400 V
400 V
Fig. 6.11 Hydraulic plan 4
Key to Fig. 6.11
16 External sensor (AF)
25 Circulation pump
27 CH pump
30 Non-return valve
31 Control valve with position indication
32 Cap valve
33 Air separator/Dirt filter
42a Expansion relief valve
42b Expansion vessel
43 Safety group for hot water pipe
46 3-way mixer valve
VF1 Buffer cylinder head temperature sensor
VF2 Supply temperature sensor
RF1 Buffer cylinder base temperature sensor
SP Cylinder temperature sensor
WQ Heat source circuit
KW Cold water
Electrical installation 6